Spot Monitor

Description:

Features and Benefits
  • Best-in-class accuracy and performance for neonate through adult patients
  • Blood pressure averaging to help ensure accurate hypertension diagnosis
  • Allows clinician to safely leave room while BP averaging is running
  • Partnerships with more than 90 leading EMRs including Epic and Cerner
  • SureBP technology provides BP in only 15-seconds - 3X faster than competitors
  • Connex Scoring App on-device calculator for custom protocols like NEWS, MEWS
  • Choice of leading SpO2 technologies: Masimo®, Nellcor® or Nonin®
  • Mobile stand option including work surface w/integrated battery for extended usage
  • Connects to select Health O Meter® digital scales. Click here for the Health O Meter Scales
  • Power Supply (7000-PS) is included with the purchase.
Materials Included
  • Connex Spot Monitor
  • (1) Adult Blood Pressure Cuff
  • (1) Large Adult Blood Pressure Cuff
  • (1) 5 ft Blood Pressure Tubing
  • (1) Lithium Ion Battery
  • (1) Hospital Grade Cord
  • (1) Power Supply
  • (1) SureTemp or Braun Pro 6000 Thermometer (Optional)
  • (1) Nonin, Nellcor or Masmio SpO2 (Optional)
  • User Manual
Note: If you order a mounting option with your Connex Spot Monitor, the power supply is included with the mounting option. See mounting options below:

Technical Specifications
  • Physical Specifications
    • Characteristics
      • Electrical rating: 100 – 240 V AC, 50 – 60 Hz, 0.8X– 1.5 A
      • Duty cycle: Continuous operation
      • Type of protection against electric shock: Class I internally powered
      • Degree of protection against electric shock, for parts applied to patients
        • Type BF defibrillator proof
        • IEC EN 60601-1, 2nd and 3rd Editions
      • Recovery time following defibrillator discharge: Less than or equal to 10 seconds
      • Dimensions
        • Height
          • Standard: 6.3 in. (16.1 cm )
          • Extended: 6.5 in. (16.6 cm ) with Braun 6000
          • Extended: 6.4 in. (16.6 cm ) with SureTemp
        • Width
          • Standard: 9.2 in. (23.4 cm )
          • Extended: 11.7 in. (29.8 cm ) with Braun 6000
          • Extended 11.7 in. (29.8 cm ) with SureTemp
        • Depth
          • Standard: 2.3 in. (5.8 cm )
          • Extended: 4.4 in. (11.0 cm ) with Braun 6000
          • Extended: 4.2 in. (10.6 cm ) with SureTemp
      • Weight
        • Standard: 2.9 lb (1.3 kg )
        • Extended: 3.7 lb (1.7 kg ) with Braun 6000
        • Extended: 3.5 lb in. (1.6 kg ) with SureTemp
    • Graphic Display Resolution
      • Dimensional Outline
        • Width: 6.5 in. (103.8 mm)
        • Height: 4.1 in. (164.9 mm)
        • Depth: 0.13 in. (3.40 mm)
      • Active Area
        • Width: 6.1 in. (154.08 mm)
        • Height: 3.4 in. (85.92 mm)
      • Resolution: 800 x 480 pixels
      • Pixel arrangement: RGB (red, green, blue)
      • Pixel Size: 63.2 μm (W) x 179 μm (H)
      • Luminance: 530 cd/m2
    • Speaker Volume
      • Luminance: 530 cd/m2
    • Alarm and Pulse Tones
      • Pulse frequency: 150 – 1000 Hz
      • Number of harmonic components in the range 300 Hz to 4000 Hz: Minimum of 4
      • Effective pulse duration:
        • High Priority: 75 –200 ms
        • Medium and Low Priority: 125 – 250 ms
      • Rise Time: 10 10 – 20% of rise time
  • Battery Specifications
    • 2 Cell Battery Specifications
      • Continuous run time (Nellcor): 5.22 hours of use
      • 6 patients/hour - 41 patient cycles (Nellcor): 6.83 hours of use
      • 8 patients/hour - 54 patient cycles (Nellcor): 6.78 hours of use
      • 8 patients/hour - 55 patient cycles (Nonin): 6.90 hours of use
      • Acute care continuous 10 minute cycles - 49 patient cycles - BP, temp, SpO2, no radio, no scanner (Nellcor): 8.22 hours of use
      • Acute care continuous 10 minute cycles - 50 patient cycles - BP, temp, SpO2, no radio, no scanner (Nonin): 8.37 hours of use
      • Acute care continuous 10 minute cycles - 49 patient cycles - BP, temp, SpO2, no radio, no scanner (Masimo): 8.29 hours of use
      • Acute care continuous 10 minute cycles - 41 patient cycles - BP, temp, SpO2, radio, scanner (Nellcor): 6.84 hours of use
      • Acute care continuous 10 minute cycles - 41 patient cycles - BP, temp, SpO2, radio, scanner (Nonin): 6.96 hours of use
      • Acute care continuous 10 minute cycles - 41 patient cycles - BP, temp, SpO2, radio, scanner (Masimo): 6.90 hours of use
  • Nurse Call
    • Nurse Call: 25 V AC or 60 V DC maximum at 1A maximum
  • NIBP specifications
    • Cuff pressure range: Meets or exceeds IEC/ISO 80601-2-30 standards for cuff pressure range
    • Systolic range
      • Adult: 30 to 260 mmHg
      • Pediatric: 30 to 260 mmHg
      • Neonate: 20 to 120 mmHg
    • Diastolic range
      • Adult: 20 to 220 mmHg
      • Pediatric: 20 to 220 mmHg
      • Neonate: 10 to 110 mmHg
    • Cuff Inflation Target
      • Adult:160 mmHg
      • Pediatric: 140 mmHg
      • Neonate: 90 mmHg
    • Maximum Target Pressure
      • Adult: 280 mmHg
      • Pediatric: 280 mmHg
      • Neonate: 130 mmHg
    • Blood pressure determination time
      • Typical: 15 seconds
      • Maximum: 150 seconds
    • Blood pressure accuracy
      • Meets or exceeds ANSI.AAMI SP10:2002 standards for noninvasive blood pressure accuracy (±5 mmHg mean error, 8 mmHg standard deviation)
    • Mean Arterial Pressure (MAP) range (The formula used to calculate MAP yields an approximate value
      • Adult: 23 to 230 mmHg
      • Pediatric: 23 to 230 mmHg
      • Neonate: 13 to 110 mmHg
    • Pulse rate range (Using blood pressure determination)
      • Adult: 30 to 200 bpm
      • Pediatric: 30 to 200 bpm
      • Neonate: 35 to 220 bpm
    • Pulse rate accuracy (Using blood pressure determination): ±5.0% (±3 bpm)
    • Overpressure cutoff
      • Adult: 300 mmHg ±15 mmHg
      • Pediatric: 300 mmHg ±15 mmHg
      • Neonate: 150 mmHg maximum
  • Temperature Specifications
    • SureTemp Plus Temperature Module Specifications
      • Temperature Range: 80°F to 110°F (26.7°C to 43.3°C)
      • Calibration Accuracy: ±0.2°F (±0.1°C) (Direct mode)
    • Braun ThermoScan Pro 6000 Specifications
      • Temperature Range: 68°F to 108°F (20°C to 42.2°C)
      • Calibration Accuracy:
        • ±0.4°F (±0.2°C) for temperatures ranging from 95.9°F to 107.6°F (35.5°C to 42°C)
        • ±0.5°F (±0.25°C) for temperatures outside of this range
      • Display Resolution: 0.1°F or °C
  • SpO2 Specifications
    • Pulse Rate: 25 to 240 beats per minute (bpm) ± 3 digits (no motion)
    • Detected pulse rate: 20 to 250 beats per minute (bpm) ± 3 digits
    • Nonin Sensor Accuracy Guide
      • SpO2 accuracy testing is conducted during induced hypoxia studies on healthy, non-smoking, light-todark-skinned subjects during motion and no-motion conditions in an independent research laboratory
      • The measured arterial hemoglobin saturation value (SpO2) of the sensors is compared to arterial hemoglobin oxygen (SaO2) value, determined from blood samples with a laboratory co-oximeter.
      • The accuracy of the sensors in comparison to the cooximeter samples measured over the SpO2 range of 70 – 100%.
      • Accuracy data is calculated using the root-mean-squared for all subjects, per ISO 9919:2005, Standard Specification for Pulse Oximeters for Accuracy.
    • Perfusion
      • 40–240 BPM. Adult/Ped
      • +/- 3 digits; Neonate
      • +/- 3 digits
    • Pulse Rate
      • 18 to 321 beats per minute (bpm)
      • No motion (18 to 300 bpm): ± 3 digits
      • Motion (40 to 240 bpm): ± 5 digits
    • Saturation
      • Adult/Pediatrics
        • Percentage: 70% to 100%
        • No Motion
          • Finger Clip: ± 2 digits
          • Flex: ± 3 digits
          • Soft Sensor: ± 2 digits
          • 8000R: ± 3 digits
          • 8000 Q: ± 4digits
        • Motion
          • Finger Clip: ± 2 digits
          • Flex: ± 3 digits
          • Soft Sensor: ± 3 digits
        • Low Perfusion
          • All Sensors: ± 2 digits
      • Neonates
        • Percentage
        • No Motion
          • Finger Clip: ± 3 digits
          • Flex: ± 3 digits
          • Soft Sensor: N/A
          • 8000R: N/A
          • 8000 Q: N/A
        • Motion
          • Finger Clip: ± 3 digits
          • Flex: ± 4 digits
          • Soft Sensor: ± 4 digits
        • Low Perfusion
          • All Sensors: ± 3 digits
  • Environmental Specifications
    • Operating Temperature: 50°F to 104°F (10°C to 40°C)
    • Storage Temperature: -4°F to 122°F (-20°C to 50°C)
    • Operating Altitude: -1250 to 10,000 ft. (-381 m to 3,048 m)
    • Operating Humidity: 15% to 90% Non-condensing
    • Storage Humidity: 15% to 95% Non-condensing
  • Monitor Radio
    • Wireless Network Interface: IEEE 802.11 a/b/g/n
    • Frequency
      • 2.4 GHz frequency bands: 2.4 GHz to 2.483 GHz
      • 5 GHz frequency bands: 5.15 GHz to 5.35 GHz, 5.725 GHz to 5.825Ghz
    • Channels
      • 2.4 GHz: Up to 14 (3 non-overlapping); country-dependent
      • 5 GHz: Up to 23 non overlapping; country-dependent
    • Antenna: Ethertronics WLAN_1000146
    • Authentication/Encryption
      • Wireless Equivalent Privacy (WEP, RC4 Algorithm)
      • Wi-Fi Protected Access (WPA)
      • EEE 802.11i (WPA2)
      • TKIP, RC4 Algorithm
      • AES, Rijndael Algorithm
      • Encryption Key Provisioning
      • Static (40- bit and 128-bit lengths)
      • PSK
      • Dynamic
      • EAP-FAST
      • EAP-TLS
      • EAP-TTLS
      • PEAP-GTC 1 PEAPMSCHAPv2
      • PEAP-TLS
    • Antenna: Ethertronics WLAN_1000146
    • Wireless Data Rates
      • 802.11a (OFDM): 6, 9, 12, 18, 24, 36, 48, 54 Mbps
      • 802.11b (DSSS, CCK): 1, 2, 5.5, 11 Mbps
      • 802.11g (OFDM): 6, 9, 12, 18, 24, 36, 48, 54 Mbps
      • 802.11n (OFDM,HT20,MCS 0-7): 6.5,13,19.5, 26, 39,52, 58.5, 72.2 Mbps
    • Agency Approvals
      • US: FCC Part 15.247 Subpart C, FCC Part 15.407 Subpart E
      • Europe: EN 300 328 (EDR) (v1.8.1), EN 300 328 (LE) (v1.8.1), EN 301 489-1 (v1.9.2), EN 301 489-17 (v2.2.1), EN 301 489-17 (v2.2.1), EN 62311:2008, EN 60950-1
      • Canada: (IC) RSS-210 standard. IC 3147A-WB45NBT based on FCC testing Singapore: Complies with IDS standard
    • Protocols: UDP, DHCP, TCP/IP
    • Data Transfer Protocols: UDP/TCP/IP
    • Output Power: 39.81mW typical, country-dependent
    • Ancillary IEEE standards: 802.11d, 802.11e, 802.11h, 802.11i, 802.1X
  • Bluetooth Module
    • Wireless Specification
      • Bluetooth: 2.1 + EDR
      • Frequency: 2.402 - 2.480 GHz
      • Maximum Transmit Power: Class 1 +8 dBm from antenna
      • Receive Sensitivity: -89 dBm
      • Range Circa: 100 meters
      • Data Rates: Up to 3 Mbps (over the air)
    • Host Interface
      • USB: Full speed USB 2.0
      • GPIO: Four configurable lines (1.8V/3.3V configurable by VDD_PADS
    • Operational Modes
      • HCI: Host Controller Interface over USB
      • HID Proxy Mode: Human Interface Device
    • EEPROM
      • 2-wire
      • 64K bits
    • Coexistence
      • 802.11 (WiFi): Three wire CSR schemes supported (Unity-3, Unity-3e, and Unity+)
    • Supply Voltage: Supply 5V ± 10%
    • Power consumption:
      • Current
        • Idle mode ~5 mA
        • File transfer ~58 mA
    • Atennna Option
      • Internal: Multilayer ceramic antenna with up to 41% efficiency
    • Physical
      • Dimensions
        • 8.5 × 13 × 1.6 mm (BT800 module)
        • 16 × 43 × 11 (BT820 USB dongle)
    • Environmental
      • Operating: -30 °C to 85 °C
      • Storage: -40 °C to 85 °C
    • Miscellaneous: Lead free Lead-free and RoHS compliant
    • Approvals
      • Bluetooth: Controller subsystem approved
      • FCC / IC / CE: All BT800 series
Warranty Information
  • 2-Year Warranty