EDAN F6 DUAL FETAL MONITOR (TWINS FHR)
EDAN F6 DUAL FETAL MONITOR (TWINS FHR)

Vendor: Edan

Description:

F6 is a high end hospital grade monitor designed for multi-bed units with central station yet simple enough for private practice, it offers the most advanced integrated monitoring for the delivery room in big hospital; private obstetrician's office; antepartum clinic. F6 are designed for use in moving situation covers the entire continuum of antepartum and intrapartum applications.

Features:

  • Basic parameters: FHR, TOCO, Event Mark, AFM
  • Optional Dual FHR monitoring
  • Optional Internal parameters: IUP/DECG
  • 24 hours waveforms playback
  • Optional Built-in wireless module
  • 150/152mm wide paper printing
  • Support American/International standard
  • 1, 2, 3cm/min real-time printing speeds
  • Quick printing for stored waveform
  • Lithium battery for 4 hours continuous working
  • 10.2 - inch high resolution color folding up LCD screen
  • Probe rack and wall mounting rack
  • Handle for easy carry
  • Optional Fetal Stimulators
  • Multi-crystal pulse wave Doppler waterproof transducer for FHR detection
  • Signals Overlap Verification

Technical Specifications:

Physical Characteristics

  • Dimensions: 347mm x 330mm x 126mm
  • Weight: 6 kg. approx.

Display

  • 10.2 inches color TFT-LCD
  • Resolution: 800 x 480

Printing

  • Recorder: 1,2,3/cm./min. real printing speed. Fast print speed (stored traces) up to 25mm/sec.
  • Recording Paper: 150/152mm, Z-Fold, thermosensitive, American/International Standard

Ultrasound

  • Technique: Ultrasound Pulse Doppler with correlation
  • Pulse repetition rate: 2 KHz
  • Ultrasound Frequency: 1.0MHz+10%
  • FHR range: 50bpm-240bpm
  • Resolution: 1bpm
  • Accuracy: ±2bpm

DECG

  • Technique: Peak - Peak detection technique
  • FHR range: 30bpm-240bpm
  • Resolution: 1bpm
  • Accuracy: ±1bpm
  • Input Impedance: >10M (Differential)
  • Input Impedance: >20M (Common Mode)

TOCO

  • TOCO range: 0-100 Relative (%)
  • Resolution: 1%
  • Zero mode: Auto/Manual
  • Non-linear error: ≤±10%

IUP

  • Pressure range: 0-100 mmHg
  • Resolution: 1%
  • Zero mode: Auto/Manual
  • Non-linear error: ±3mmHg

Auto Fetal Movement (AFM)

  • Technique: Pulsed Doppler ultrasound
  • Range: 0-100 (%)
  • Resolution: 1%

Marking

  • Manual fetal movement mark

Battery

  • 14.8 V rechargeable Lithium-ion battery
  • Continuous working time: 2-4 hours

Communication port

  • DB9 network interface, RJ45 interface