Criticare 8100E-ST nGenuity Patient Monitor w/ ST, Arrythmia

Vendor: Criticare

Description:

The innovative user interface features simplified menus and dedicated function keys for timely set-ups. The big, bright display with large numerics can easily be seen, even from across the room.

Features and Benefits
  • Standard: ECG, ComfortCuff™ NIBP, DOX™ SpO2, HR, Temperature, Respiration, and Nurse Call interface connection.
  • Easy-to-read 10.4" active TFT color display - view up to 6 waveforms simultaneously.
  • Easy to learn, easy to use menus, dedicated function keys, and simplified controls.
  • Arrhythmia and ST Analysis Software is included
    • The arrhythmia and ST analysis software extension has the capability to measure ST segment deviations and generate arrhythmia alerts for common ventricle arrhythmia conditions.
    • The arrhythmia and ST alerts can also have user specified alarm levels.
    • The monitor measures ST segments continuously from the real-time waveform collected by the internal ECG module.
    • ST elevations are reported on-screen as current numerical values, as short term graphs and long term trends.
    • The arrhythmia and ST analysis is fully integrated with the standard ECG package of the monitor.
Materials Included
  • 8100E-ST Patient Monitor
  • (1) SpO2 Adult Sensor
  • (1) Child/Small Adult BP Cuff
  • (1) Adult BP Cuff
  • (1) Large Arm Adult BP Cuff
  • (1) NIBP Hose
  • (1) Rechargeable Battery
  • (1) ECG Cable Assembly.
  • (3) ECG Electrodes
  • (1) Power Cord
  • (1) Arrhythmia and ST Analysis Software
  • User Manual
Technical Specifications
  • ECG
    • Connectors: 3- or 5-lead
    • Leads: User-selectable; I, II, III, aVR, aVL, aVF, V (5-lead); I, II, or III (3-lead)
    • Gain Selection: x1/2, x1, x2, and x4
    • Electrosurgery Protection: Yes
    • Defibrillator Protection: Yes
    • Pacer Detection/Rejection: Yes
  • Non-Invasive Blood Pressure
    • Technique: Oscillometric measure upon inflation
    • Automatic Measurement Cycles: 2, 3, 5, 10, 15, 30 min; 1, 2, 4 hr
    • Measurement Range: Adult: 30 to 300mmHg; Neonate: 0 to 150 mmHg
    • Resolution: 1mmHg
    • Transducer Accuracy: ±2mmHg or ±2%, which ever is greater
    • STAT mode: 5 min of consecutive readings
  • Pulse Oximetry
    • Range: 1% to 99%
    • Resolution: 1%
    • Accuracy:
      • 70% to 99% range: ±2%
      • 50% to 69% range: ±3%
      • <50%: unspecified
    • Method: Dual wavelength LED
  • Heart (Pulse) Rate
    • Source: ECG (primary); Pleth; NIBP
    • Range: 20 to 300 bpm (30-240 bpm, NIBP)
    • Accuracy: ±1bpm or ±1% (ECG); ±2 bpm or ±2% (NIBP)
  • ST Analysis
    • Lead Views: I, II, III, aVR, aVL, aVF, V
    • Elevation Accuracy: Greater of ± 0.2 mm of 5%
    • Method: 16 Beat Average
    • Range: - 6.0 mm to + 6.0 mm
    • Resolution: 0.1 mm
  • Arrhythmia Detection
    • PVC Detection:
      • Rates from 2 to 255 per minute
      • Runs: 2 to 6
    • Ventricle Tachycardia Alarm: Adjustable
    • High Priority Alarms:
      • Heart Rate
      • Asystole
      • Tachycardia
      • Ventricular Fibrillation
      • Bradycardia
      • Ventricular Tachycardia
  • Display (For ST and Arrhythmia)
    • Main Display:
      • Numerical PVC Rate
      • ST Elevation Numerics for 3 leads
    • Waveforms: Up to 6 ECG waveforms, selectable
    • Elevation Graphs:
      • 3-leads recorded in waveform slots
      • Time Scales: 5, 10, 25, 30, 60 minutes
      • Ventricle Scale: ±1 mm to ± 6 mm
  • Trends (For ST and Arrhythmia)
    • Graphical and Tabular:
      • ST-I, ST-II, ST-III, ST-AVR, ST-AVL, ST-AVF, STV, PVC Rate
  • Temperature
    • Channels: 1
    • Range, Accuracy: 68° to 113° F (20° to 45° C): ±0.1° C
    • Probe: YSI-400 and YSI-700 series
  • Respiration
    • Rate: 6 to 150 breaths/min
    • Resolution: 1 breath/min
    • Accuracy: ±1% or ±1 breath/min, whichever is greater
    • Source: ECG-TTI
  • Alarms
    • Indication: Audible; visual
    • Silence: Yes; 2 min or permanent
  • Trend Memory
    • Memory: 24 hr at 30 sec intervals
    • Display: Tabular, Graphical
  • Display
    • Screen: 10.4" active color TFT
    • Resolution: 640 x 480 pixels
    • Waveforms: 6, maximum
    • Languages: English, French, German, Italian, Portuguese, Spanish, Russian, Chinese
  • Controls
    • Keys: 9; membrane-activated
    • Rotary Knob: Push and rotate; 24 steps/turn
  • System Outputs
    • Com Ports: RS 232-compatible; DB9 (Com 1)
    • Nurse Call: Contact switch; 3.5mm stereo phone jack, standard 14mm length
    • Defib/Sync: BNC connector
    • Video Port: High density D-sub 15-pin
  • Mechanical
    • Weight: 14 lb; 6.4kg
    • Size: Base unit: 11" (H) x 13" (W) x 10.3" (D); 28cm (H) x 33cm (W) x 26.2cm (D)
  • Power Requirements
    • Voltage: 100, 120, 220, 240 VAC; 50/60 Hz
    • Consumption: 35 W, typical
    • Batteries: 1; sealed lead acid; life: 3 hr, typical; recharge time: 4.5 hr
  • Environmental
    • Operating Temperature: 59° to 95° F; 15° to 35° C
    • Storage Temperature: 23° to 122° F; -5° to 50° C
    • Operating Humidity: 15% to 90%, non condensing
  • Classification
    • Medical Device: Class II Equipment (IIb EU)
    • Electrical Protection: Class I Equipment
    • Degree of Protection: Type CF, Defib-proof
    • Protection Against Ingress: IPX1
Office Management Software Compatibility – CSI products are compatible with the following OMS products below. 
  • Kodak WINOMS CS by Carestream Dental LLC
  • TiME for OMS by Decision Base, Inc.
  • U.S. HealthRecord powered by TeamLINKS, Inc.
  • Oral Surgery-Exec® by DSN Practice Management Software
  • OMSVision® by HenrySchein Practice Software
  • Windent® by Carestream Dental LLC
  • MD-REPORTS
  • ProVation® Medical
  • gMed
  • Endosoft®
Warranty Information
  • 2-Year Warranty.