Criticare 81H001XD nCompass Vital Signs Monitor w/ CO2
Criticare 81H001XD nCompass Vital Signs Monitor w/ CO2

Vendor: Criticare

Description:

The nCompass™ 81H001XD monitor is the perfect choice for busy departments demanding accurate, reliable performance.

Features and Benefits
  • Easy-to-read 12.1" active color TFT display.
  • Easy to learn, easy to use with simplified menus and dedicated function keys.
  • Mini-Trends can display condensed tabular vital signs data to show recent monitoring activities.
  • Cardio-Respirogram Trend Display.
  • Compatible with popular Electronic Medical Records (EMR) systems for both large and small offices.
  • CO2 monitoring incorporates CSI’s patented water trap design with full occlusion clearing.
  • Monitor mounts quickly and easily to walls and roll stands.
Materials Included
  • (1) 81H001XD Vital Signs Monitor
  • (1) Adult SpO2 Sensor
  • (1) NIBP Hose
  • (1) Child/Small Adult NIBP Cuff
  • (1) Adult NIBP Cuff
  • (1) Large Adult NIBP Cuff
  • (1) ECG Cable
  • (3) Electrodes
  • (1) Rechargeable Battery
  • (1) Power Cord
  • (1) CO2 Sidestream
  • (1) CO2 Sensor
  • (5) Water Traps
  • (5) Sample Line
  • User Manual
Technical Specifications

ECG
  • Number of Leads: 3- or 5-Lead
  • Lead View: User-selectable; I, II, III, aVR, aVL, aVF, V (5-Lead); I, II, or III (3-Lead)
  • Gain Selection: x0.5, x1, x2, and x4
  • Frequency Response: Diagnostic: 0.05 to 100 Hz (-3dB);
  • Monitor: 0.5 to 40 Hz (-3dB);
  • ST: 0.05 to 40 Hz (-3dB)
  • Electrosurgery Protection: Yes
  • Defibrillator Protection: Yes
  • Pacer Detection/Rejection: Yes
  • ST Accuracy: ±0.2 mm or ±5% of reading, whichever is greater, over heart range of 30 to 120 bpm
  • ST Range: -6.0 to 6.0 mm
NIBP (Non-Invasive Blood Pressure)
  • Technique: Oscillometric measure upon inflation
  • Measurement Cycle: < 40 sec. typical
  • Auto. Measurement Cycles: 2, 3, 5, 10, 15, 30 min; 1, 2, 4 hr
  • Max. Allowable Cuff Pressure: Adult/Pediatric: 300 mmHg; Neonate: 150 mmHg
  • Range: Adult/Pediatric: 30-300 mmHg; Neonate: 20-150 mmHg
  • Resolution: 1 mmHg
  • Transducer Accuracy: ±2 mmHg or ±2% or reading, whichever is greater,
  • over full range
  • STAT Mode: 5 min of consecutive readings
  • Clinical Accuracy: Complies with AAMI SP-10:2002
Pulse Oximetry
  • Range: 1% to 99%
  • Resolution: 1%
  • Accuracy: 70% to 99% range: ±2%; 50% to 69% range: ±3%;
  • < 50%: unspecified
  • Method: Dual wavelength LED
Heart (Pulse) Rate
  • Source: User selectable: Smart, ECG, Pleth, NIBP, IBP
  • Range: 20 to 300 bpm (ECG, Pleth);
  • 30-240 bpm (NIBP); 30-300 bpm (IBP)
  • Accuracy: ±1 bpm or ±1% (ECG) whichever is greater
Temperature
  • Channels: 2
  • Range, Accuracy: 68° to 113°F (20° to 45°C): ±0.1°C
  • Display Resolution: ±0.1°
  • Probe: YSI-400 and YSI-700 Series
Respiration
  • Rate: 6 to 150 bpm (ECG); 2 to 120 bpm (CO2)
  • Resolution: 1 bpm
  • Accuracy: ±2 bpm or ±2%, whichever is greater
  • Source: User selectable: Smart, CO2, ECG
CO2
  • Units: mmHg; %; kPa; Torr.
  • Method: Non-dispersive infrared; autocalibrating.
  • N2O Compensation: Manual (On/Off).
  • Range: 0–99 mmHg; 0–12.5%; 0–12.5 kPa; 0–99Torr.
  • Resolution: 1 mmHg; 0.1%; 0.1 kPa; 1 Torr.
  • Flow, Sample Rate: 200 ml/min.
  • Accuracy: ±2 mmHg; ±0.3 vol. %; ±0.3 kPa; ±2 Torr or ±4% of reading, whichever is greater, at 200 ml/min & respiratory rate of ≤ 120 bpm.
  • Rise Time: 170 ms (10–90%) at 200 ml/min.
Alarms
  • Indication: Audible; Visual (EN 60601-1-8)
  • Silence: Yes; 2 minutes or permanent.
Trends
  • Memory: 24 hours at 30 second intervals.
  • Display: Tabular, Graphical.
Display
  • Screen: 12.1” active color touch screen
  • Waveforms: 6, maximum
  • Waveform Types: ECG Leads I, II, III, aVR, aVL, aVF, V; CO2; Respiration; Pleth; IBP; breath-by-breath CO2; ST Histograms; Mini-Trends; OXY-CRG
  • Sweep Speed: 6.25, 12.5, 25, or 50 mm/sec
Controls
  • Keys: 10; membrane-activated.
  • Rotary Knob: Push and rotate; 24 steps/turn.
System Outputs
  • COM ports: Two RS232-compatible DB9 ports; USB (for software downloads only).
  • Nurse Call: Contact switch; 3.5 mm stereo phone jack, 14 mm.
  • Defib/Sync BNC connector.
  • Video Port: Serial VGA compatible.
  • DC Out: 5 VDC output for optional wireless accessory.
  • External Module Port: 8-PIN circular connector.
Physical Properties
  • Weight: 12 lbs; 5.4 kg.
  • Size: 12” (H) x 14.5” (W) x 11.5” (D);
  • 30.5 cm (H) x 36.8 cm (W) x 29.2 cm (D)
Power Requirements
  • Voltage: 100 to 240 VAC; 50/60 Hz.
  • Power Consumption: 35 W, typical.
  • Battery: 1 sealed lead acid.
  • Battery Life: 2 hours, typical (3 hours, typical for base unit).
  • Recharge Time: 4 to 6 hours, typical.
Environmental
  • Operating Temperature: 32° to 104°F (0° to 40°C).
  • Storage Temperature: 23° to 122°F (-5° to 50°C).
  • Operating Humidity: 15% to 90%, noncondensing.
  • Operating Altitude: -300 to 3,000 meters.
Classification
  • Medical Device: Class II Equipment (IIb EU).
  • Electrical Protection: Class I Equipment.
  • Degree of Protection: Type CF, Defibrillator-proof.
  • Protection Against Ingress: IPX1.
  • Safety: EN 60601-1.
Office Management Software Compatibility – CSI products are compatible with the following OMS products below. 
  • Kodak WINOMS CS by Carestream Dental LLC
  • TiME for OMS by Decision Base, Inc.
  • U.S. HealthRecord powered by TeamLINKS, Inc.
  • Oral Surgery-Exec® by DSN Practice Management Software
  • OMSVision® by HenrySchein Practice Software
  • Windent® by Carestream Dental LLC
  • MD-REPORTS
  • ProVation® Medical
  • gMed
  • Endosoft®
Warranty Information
  • 2-year warranty.