Criticare 8100EP1-ST nGenuity Patient Monitor w/ ST, Arrythmia, Printer

Vendor: Criticare

Description:

The nGenuity™ patient monitor is the perfect choice for busy practices demanding accurate, reliable performance. Compact and lightweight, the nGenuity™ patient monitor can monitor adults, pediatrics and neon.

The capnography modules uses sidestream sampling and Criticare's patented WaterChek™ water traps to remove moisture without distortion to the CO2 waveform. The water traps have a large 22 mL reservoir and full occlusion clearing capability unlike many other CO2 monitoring systems.

Features and Benefits

  • Monitors End-tidal CO2 and inspired CO2 accurately at high respiration rates.
  • Gas Monitoring with full occlusion clearing and high capacity water trap.
  • Mini-Trends can display condensed tabular vital signs data to show recent monitoring activity.
  • Compatible with popular Electronic Medical Records (EMR) systems for both large facilites and small offices.
  • Easy-to-read 10.4" active TFT color display.
  • Easy to learn, easy to use -- simplified menus and dedicated function keys.
  • Monitor can mount quickly and easy to a wall or rolling stand
  • Simple-to-use, lightweight, and portable design.
  • Monitor comes with an integrated printer
  • Arrhythmia and ST Analysis Software is included
    • The arrhythmia and ST analysis software extension has the capability to measure ST segment deviations and generate arrhythmia alerts for common ventricle arrhythmia conditions.
    • The arrhythmia and ST alerts can also have user specified alarm levels.
    • The monitor measures ST segments continuously from the real-time waveform collected by the internal ECG module.
    • ST elevations are reported on-screen as current numerical values, as short term graphs and long term trends.
    • The arrhythmia and ST analysis is fully integrated with the standard ECG package of the monitor.
Materials Included
  • 8100EP1 Patient Monitor Unit
  • (1) SpO2 Adult Sensor
  • (1) Child/Small Adult NIBP Cuff
  • (1) Adult BP Cuff Quick Connect.
  • (1) Large Arm Adult BP Cuff.
  • (1) NIBP Hose - 10ft. Straight.
  • (1) ECG Cable Assembly.
  • (3) ECG Electrodes
  • (1) Power Cord
  • (1) Printer
  • (1) CO2 Sidestream
  • (1) CO2 Sensor
  • (5) Water Traps
  • (5) Sample Line
  • (1) Arrhythmia ST Analysis Software
  • Operator's Manual
Technical Specifications
  • Dimensions:
    • Width: 13"
    • Height: 11"
    • Depth: 10.3"
  • Weight: 14 lbs
  • ECG
    • Number of Leads: 3- or 5-lead
    • Lead View: User-selectable; I, II, III, aVR, aVL, aVF, V (5-lead); I, II, or III (3-lead)
    • Gain Selection: x1/2, x1, x2, and x4
    • Frequency Response: Diagnostic: 0.05 to 100 Hz (-3dB)
    • Monitor: 0.5 to 40 Hz (-3dB)
    • Electrosurgery Protection: Yes
    • Defibrillator Protection: Yes
    • Pacer Detection/Rejection: Yes
  • ST Analysis
    • Lead Views: I, II, III, aVR, aVL, aVF, V
    • Elevation Accuracy: Greater of ± 0.2 mm of 5%
    • Method: 16 Beat Average
    • Range: - 6.0 mm to + 6.0 mm
    • Resolution: 0.1 mm
  • Arrhythmia Detection
    • PVC Detection:
      • Rates from 2 to 255 per minute
      • Runs: 2 to 6
    • Ventricle Tachycardia Alarm: Adjustable
    • High Priority Alarms:
      • Heart Rate
      • Asystole
      • Tachycardia
      • Ventricular Fibrillation
      • Bradycardia
      • Ventricular Tachycardia
  • Pulse Oximetry
    • Range: 1% to 99%
    • Resolution: 1%
    • Accuracy:
      • 70% to 99% range: ±2%;
      • 50% to 69% range: ±3%;
      • <50%: unspecified
      • Method: Dual wavelength LED
  • Display (For ST and Arrhythmia)
    • Main Display:
      • Numerical PVC Rate
      • ST Elevation Numerics for 3 leads
    • Waveforms: Up to 6 ECG waveforms, selectable
    • Elevation Graphs:
      • 3-leads recorded in waveform slots
      • Time Scales: 5, 10, 25, 30, 60 minutes
      • Ventricle Scale: ±1 mm to ± 6 mm
  • Trends (For ST and Arrhythmia)
    • Graphical and Tabular:
      • ST-I, ST-II, ST-III, ST-AVR, ST-AVL, ST-AVF, STV, PVC Rate
  • Non-Invasive Blood Pressure
    • Technique: Oscillometric during Inflation
    • Inflation Pressure Range: Adult/Pediatric: 30 to 300 mmHg
    • Neonate: 20 to 150 mmHg
    • Measurement Cycle: < 40 sec. average
    • Auto. Measurement: 2, 3, 5, 10, 15, 30 min; 1, 2, 4 hour intervals
    • STAT Mode: 5 minutes of consecutive readings
    • Resolution: 1mmHg
    • Transducer Accuracy: ±2mmHg or ±2%, whichever is greater
    • Clinical Accuracy: Complies with AAMI SP-10:2002
  • Heart (Pulse) Rate
    • Source: User selectable: Smart, ECG, Pleth, NIBP
    • Range: 20 to 300bpm (30-240bpm, NIBP)
    • Accuracy: ±1bpm or ±1% (ECG), whichever is greater
  • Temperature
    • Channels: 1
    • Range, Accuracy: 68° to 113° F (20° to 45° C): ±0.1° C
    • Display Resolution: ±0.1° C
    • Probe: YSI-400 and YSI-700 series
  • Trends
    • Memory: 24 hr at 30 second intervals with an NIBP reading every 3 minutes.
    • Display: Tabular, Graphical
  • Interface & Display
    • Keys: 9; membrane-activated
    • Rotary knob: Push and rotate; 24 steps/turn
    • Screen: 10.4" active color TFT
    • Resolution: 640 x 480 pixels
    • Waveforms: 6, maximum
    • Waveform Types: ECG leads I, II, III, aVR, aVL, aVF, V; Respiration; CO2, Pleth; ST Histograms
    • Sweep Speed: 6.25, 12.5, 25, 50mm/sec
    • Languages: English, French, German, Italian, Portuguese, Spanish, Russian, Chinese
  • System Outputs
    • Nurse Call: Contact switch; 3.5 mm phone
    • COM Port: RS232 compatible, DB9 (Com 1)
    • Defib/Sync: BNC connector
    • Video Port: High density D-sub 15-pin serial VGA compatible
  • Power Requirements
    • Voltage: 100 to 240 VAC; 50/60 Hz
    • Power Consumption: 35 Watts, typical
  • Environmental
    • Operating Temperature: 59° to 95° F; 15° to 35° C
    • Storage Temperature: 23° to 122° F; -5° to 50° C
    • Operating Humidity: 15% to 90%, non-condensing
  • Capnography (CO2)
    • Units: mmHg; %; kPa; Torr
    • Method: Non-dispersive infrared; autocalibrating
    • N2O Compensation: Manual; On/Off, user selectable
    • Range: 0 to 99mmHg; 0 to 12.5%
    • Resolution: 1mmHg; 0.1%; 0.1 kPa; 0.1 Torr
    • Flow, Sample Rate: Sidestream; 200ml/min
    • Accuracy: ±2mmHg, ±0.3 volume %, ±0.3 kPa, or ±2 Torr at 200 ml/min & respiratory rate <= 120 bpm
    • Rise Time: 170ms (10-90%) at 200ml/min
  • Printer
    • Type: Thermal line printer
    • Paper Speed: 12.5, 25, 50 mm/sec
Office Management Software Compatibility – CSI products are compatible with the following OMS products below. 
  • Kodak WINOMS CS by Carestream Dental LLC
  • TiME for OMS by Decision Base, Inc.
  • U.S. HealthRecord powered by TeamLINKS, Inc.
  • Oral Surgery-Exec® by DSN Practice Management Software
  • OMSVision® by HenrySchein Practice Software
  • Windent® by Carestream Dental LLC
  • MD-REPORTS
  • ProVation® Medical
  • gMed
  • Endosoft®
Warranty Information
  • 2-Year Warranty